WorldIndustrialWeekly General: Pack Health Records Before Cell-Level Mandates in Second-Life Batteries

A failing cell bolted under a bus floor can take 10 to 15 minutes to register on an external temperature sensor, and a pack that leaves service with an unverifiable state of health (SoH) cannot be priced, insured, or entered into a Scope 3 inventory. The change that pays back first is a machine-readable, pack-level health record, not a mandate on the radio link inside the pack. That is the sequencing call in this WorldIndustrialWeekly General field note: the physical layer is still being redesigned, while the record a second-life buyer needs is already missing. Where the money and the regulatory risk sit follows from that distinction.

What does the contactless in-pack link actually change?

It changes failure modes and sensor density, not who may read the data. Dukosi, an Edinburgh company, has begun commercial sampling of DK-NFLNK, a contactless intra-battery communication system that carries cell voltage and temperature readings over a single bus antenna instead of copper wiring, as GreencarbonWorld reported from the Pretzl Connect 2026 event in Budapest.

Joseph Notaro, the company's president, put connector failure rates in a conventional harness at around 10 parts per million, and said that in automotive and industrial settings where reliability is measured at parts-per-billion level, that rate is too high and an unacceptable risk of failure. The thermal case is the one worth time. According to the same GreencarbonWorld report, Notaro said that in traditional layouts with sparse temperature sensing, heat from a failing cell can take 10 to 15 minutes to reach an external sensor, and that sensing on every cell catches an excursion well before it reaches adjacent cells — exactly the gap that matters for a pack bolted under a bus floor and charged overnight in a depot. Dukosi also claims that consistent cell-level data can let operators reduce safety buffers and increase usable energy by 6% to 12%.

None of that settles access. A wired management system can be as opaque as a wireless one, and copper does not make a protocol open. Swapping a harness for radio changes how a pack fails; who gets to read the numbers is a separate arrangement. Our own reporting on what the contactless link must still prove — electromagnetic compatibility (EMC) and security among them — lands in the same place: the physics case is credible, the access case is not written yet.

Where does the lock-in really sit — in the wire or in the reader?

It sits in the chip-level record and in the tool that opens it, not in the copper. Dukosi says every cell carries its own digital passport on chip, recording the maximum temperature it has seen, its voltage history and total charge cycles; the same account has recyclers and integrators reading the chip to establish cell health and sort packs for grid use or recycling, as GreencarbonWorld describes. That description leaves out a reader, a licence and a permission model. It is a vendor description of a product now sampling, not an audited result, and I would treat it accordingly.

The regulatory clock runs on its own schedule. Regulation (EU) 2023/1542 sets 18 February 2027 as the date from which each light means of transport (LMT) battery, each industrial battery with a capacity greater than 2 kWh, and each electric vehicle battery placed on the market or put into service must have an electronic record — the battery passport. Annex XIII splits passport data into public, legitimate-interest and authorities-only tiers under Article 77(2), with roughly 80 attributes for electric vehicle batteries. A passport is an access regime before it is a document: what a third party may query, and on whose terms, is still being negotiated.

Why does cell-to-cell spread strengthen the pack-record case?

Because a single average SoH figure hides the weak cells that actually set a pack's usable life, and a record that carries the spread is worth more than one that carries an average. A 2026 study in Nature Energy by Zhou and colleagues, drawn from two real-world fleets, found that cell-to-cell inconsistency reduced usable pack-level SoH by 6.2% in passenger cars and 7.5% in buses, and shortened pack lifetime by 17.7% and 22.8% relative to the average lifetime of the constituent cells. For a depot the reading is blunt: an average hides the tail, and the tail sets residual value. That is why resting cell-voltage spread earns a place in the minimum field set below, and why a dispersion-aware pack record can be priced without opening the high-voltage enclosure.

What is the strongest case against waiting, and does it survive?

The timing argument is the uncomfortable one, and the only one I concede — but it does not justify a radio mandate today. Interfaces that ship before a rule exists tend to become the rule. DK-NFLNK is sampling in 2026, packs built around it will be in service years before anyone writes a conformance test, and sealed high-voltage hardware is close to impossible to retrofit with a read port afterwards. Reading a record at the pack terminals after disassembly loses the cell-level detail that made the record worth keeping, so pack-level access is not a full substitute.

Peak cell temperature, voltage history and cycle count are the fields that decide residual value, insurance terms and whether a pack is safe to install under a school. Held behind one vendor's tool, those fields shift value from the independent grader or repairer to the manufacturer every time a pack changes hands; that shift is the real fight. Dukosi sells DK-NFLNK as a step along a longer path: it says DK-NFLNK and its full cell monitoring system are built on the same C-SynQ communication platform, giving battery manufacturers a migration path to full chip-on-cell monitoring, as GreencarbonWorld reports. A rule written now would certify an interface the vendor expects to be superseded.

There is also no agreed definition of what an SoH figure means or how wide its uncertainty band should be, and freezing a number nobody can reproduce produces certified dead ends. The security objection deserves the same treatment. A general-purpose reader able to interrogate cells inside a live high-voltage pack is an attack surface, and nobody has costed the safety duty that comes with it. Authentication in that setting is a safety control that keeps people out of a pack they should not open. Regulation 2023/1542 already establishes an access regime, so a second one attached to the hardware layer would duplicate the first while adding its own failure points.

Who captures the 6% to 12%, and what does grading really cost?

Whoever can grade fastest and cheapest captures the margin; the technology alone does not decide the winner. Take the 6% to 12% usable-energy figure at face value. Behind one vendor's tool, that margin is captured in warranty, certified resale and the manufacturer's own second-life programme. Readable by any licensed grader, it spreads across every integrator able to price a pack. Same cells, different distribution of the gain.

The grading bottleneck is what makes that distribution expensive. IDTechEx forecasts the second-life EV battery market at US$4.2B by 2035 and flags battery grading time, disassembly and reassembly among the cost drivers. Retired electric school bus packs still hold nearly 70% of their capacity, according to the Electric School Bus Initiative. A 2026 study in Applied Energy by Cobb and colleagues estimated repurposing costs of about US$12 per kilowatt-hour (kWh) at pack level against US$41/kWh at module level for a Tesla Model S pack — a reminder that how far a crew strips the pack, and how quickly it can grade, swing the economics more than the chemistry does. Every pack arriving without a trustworthy history has to be cycled on a tester before an insurer or a buyer will touch it, consuming equipment hours plus the labour of safely rigging a high-voltage pack. Cell-level history is worth money because it removes some of those hours.

A thread on r/batteries raises the missing standardised health data from a buyer's point of view, and a Hacker News discussion of used packs lands in a similar place; the forum posts are not survey evidence and I would not build a business case on them. The 2024 reviews of second-life pathways by Patel et al. in Frontiers in Chemistry and by Song et al. in Energies cover that ground in more detail. Carbon accounting will not create the incentive by itself: end-of-life handling of sold products belongs in Scope 3, and a repurposed pack still has to be priced on the value a buyer can recover. Fleet buyers can move before regulators do. A bus tender requiring a machine-readable record, queryable without a vendor licence once the vehicle leaves service, changes procurement inside one contract cycle because manufacturers answer tenders faster than consultations — the logic behind a depot-level disclosure framework for fleets.

Which assumptions trip up buyers?

  • Copper makes the data open. It does not; a wired battery management system (BMS) can be as opaque as a wireless one, and openness is a protocol decision.
  • A battery passport equals data access. It does not; without query rights and tier rules, a passport is a document vault that an independent grader cannot use.
  • One SoH number is comparable across vendors. It is not; without an agreed definition and uncertainty band, two numbers can describe different measurements.
  • Pack-level reading fully replaces cell-level reading. It does not; a terminal read after disassembly loses the cell detail that made the record valuable.
  • Forum threads prove buyer demand. They signal a question, not a market; no business case should rest on them.

What should a tender require, and how do we sequence it?

Require a minimum pack-level record with a stated method and uncertainty band, and leave the intra-pack physical layer alone until chip-on-cell architectures settle. My field set: SoH with the method behind it and an uncertainty band, peak temperature seen, cycle count, and resting cell-voltage spread — machine-readable, tiered by role, readable after disassembly, with conformance tests and no licence fee for read-only access once the pack has left the vehicle. Incremental capacity analysis (ICA) is a candidate reference method for making the SoH number reproducible: a 2024 study in Batteries and a 2026 review treat ICA as an effective estimation route, which is the property a conformance bench needs.

  1. Write read access into bus and truck tenders this year, while the regulation is still in draft.
  2. Fix the minimum field set and its uncertainty band, then test both on packs already in service rather than new ones.
  3. Fund a reference bench so a health number can be checked against something other than the seller's own tool.
  4. Leave the intra-pack link alone until chip-on-cell architectures settle, then revisit with retrofit cost data.

The trigger that would prove me wrong is written down now: if the passport deadline arrives and an independent grader still cannot obtain a number it can insure without the manufacturer's permission, the sequencing argument collapses and a hardware mandate becomes the remaining option. The framework is deliberately repeatable across depots — write access into the tender, fix the fields, fund the bench, defer the link. The first item costs a procurement team a few weeks of attention and depots are buying buses this year regardless; the last costs nothing, which is usually the one that gets skipped.

— Oscar Murphy, manufacturing transformation consultant, WorldIndustrialWeekly General.

Frequently asked questions

Is a cell-level readout mandate needed for second-life batteries?

Not first. A machine-readable pack-level health record unlocks pricing, insurance and Scope 3 reporting now; the in-pack link is still being redesigned and a premature rule risks certifying an interface that gets superseded.

When does the EU battery passport become mandatory?

From 18 February 2027 under Regulation (EU) 2023/1542, for light means of transport batteries, industrial batteries greater than 2 kWh, and electric vehicle batteries placed on the market or put into service.

Can one SoH number be trusted across manufacturers?

Only if the method and uncertainty band are published. Without an agreed definition, two vendors' SoH figures can measure different things; ICA-based reporting on a reference bench is one route to comparability.

What would justify a hardware mandate instead?

If, after the passport deadline, an independent grader still cannot obtain an insurable health number without the manufacturer's permission, the access route has failed and a hardware-level read requirement becomes the remaining lever.

Reference sources

  • GreencarbonWorld: Dukosi Starts Sampling DK-NFLNK to Replace Battery Wiring With Near-Field RF
  • EUR-Lex: Regulation (EU) 2023/1542 (batteries and waste batteries)
  • Nature Energy: Quantifying the impact of cell-to-cell inconsistency on EV battery degradation and utilization (Zhou et al., 2026)
  • Applied Energy: Electric-vehicle battery second-life and recycling pathways (Cobb et al., 2026)
  • IDTechEx: Second-life Electric Vehicle Batteries 2025-2035
  • Electric School Bus Initiative: Building a Market for Second-Life Electric School Bus Batteries
  • Batteries (MDPI): State of Health Estimation for Lithium-Ion Battery Using Partial Charging and ICA
  • Frontiers in Chemistry: Lithium-ion battery second life, pathways, challenges and outlook
  • Energies: An Overview About Second-Life Battery Utilization
Brand logo

Industrial Weekly

In-Depth Weekly Insights on Manufacturing & Supply Chain

AutomationSupply ChainSmart ManufacturingLogisticsEnergyGeneralGreen CarbonWorld

© 2026 Industrial Weekly.

Cookie Notice

We use cookies to improve your experience and analyze website traffic. Read our Privacy Policy to learn more.