ISO 20270 Blocked-Force Testing, Step by Step: How NVH Teams Can Cut FRF Measurement Time by 93%

FRF characterization no longer has to depend on specialist hands. A self-measuring fixture driven under Simcenter Testlab produces blocked-force and impedance models that satisfy ISO 20270 inside a controlled process, and SieSiemens puts the saving at 93% less FRF measurement time, compressing a multi-day characterization job into hours. For lab managers and program owners, that turns a scarce-engineer bottleneck into a schedulable, auditable bench step feeding system-level NVH prediction through virtual prototyping.

What does the automated workflow actually hand over to simulation?

Conclusion first: it delivers a source-intrinsic component model, not a folder of raw curves. That distinction is why the output can be reused in assemblies that do not exist yet.

Within the standard, a blocked force is the dynamic force an operating source would apply to a fully rigid receiving structure; ISO 20270 specifies the indirect measurement route to that quantity together with guidance for keeping uncertainty under control. Because the definition is independent of the receiver, a model measured on one bench can be re-applied to another mounting. The cell outputs two paired objects - blocked forces and impedance frequency response functions (FRFs) - which are precisely the inputs required by component-based transfer path analysis and by system-level virtual assembly models.

A timeline note that matters for procurement: the standard's first edition dates from 2019, adopted nationally as BS ISO 20270:2019 on 30 November 2019 and in Europe as EN ISO 20270:2023 (see the ISO catalogue entry at iso.org/standard/90545.html). Test cells commissioned before that generation generally cannot claim compliant extraction without a hardware and software upgrade.

Why has manual characterization kept stalling development schedules?

Conclusion: the traditional method is slow, and, more damagingly, inconsistent. Engineers routinely spend days gathering data that cannot be repeated identically, and the variation flows straight into downstream simulation and system integration as uncertainty rather than as knowledge.

Three structural weaknesses explain it. First, the procedure is specialist-bound: one experienced technician and one rig become the critical path for several programs. Second, sampling plans drift between sessions - attachment positions, excitation order, adapter mounting - so two valid-looking datasets are not statistically comparable. Third, a model produced for one variant is usually re-measured when the mounting changes, which multiplies bench demand instead of amortizing it. The automated approach removes these failure modes by putting acquisition and processing into a controlled sequence that does not depend on an operator.

How do you stand the workflow up? An eight-step build order

Conclusion: build from the mechanics outward. Fixture stiffness and signal-chain topology decide data quality long before any algorithm runs.

  1. Scope the component backlog. Pick the parts tested most often per program year. The supported representation types are test-based and CAE-based, covering electric motors, pumps, compressors, steering systems and actuators.
  2. Install the self-measuring fixture. Rigid virtual-point adapters carry a permanently mounted array of shakers and accelerometers, so the load path is fixed once rather than rebuilt per test.
  3. Wire the automation chain. The automation control unit connects through an amplifier to a Simcenter SCADAS frontend, which links to a laptop running Simcenter Testlab.
  4. Confirm portfolio fit. The solution sits inside the Simcenter physical testing portfolio and pairs Simcenter Testlab software, Simcenter SCADAS hardware and Simcenter for Qsources hardware; document which element is already owned and which is incremental spend.
  5. Push the test plan to the recorder. Transferring the plan into the acquisition app on a wireless tablet gives the technician step-by-step instructions and allows immediate data verification at the bench.
  6. Run automated extraction. Blocked forces and impedance FRFs are acquired automatically, following the ISO 20270 procedure rather than an internal work-instruction.
  7. Validate and repeat. Execute a repeatability set - same component, re-mounted - before releasing the model, and keep the uncertainty checks the standard prescribes.
  8. Export and register the model. Release data in universal or third-party formats so downstream CAE teams are not locked to one toolchain, then enter the model into a versioned library that multiple system variants can call.

Where did the industrial recipe come from, and what does the Bosch case show?

Conclusion: this is a co-development result, not a lab demo. The approach was created with Bosch and builds on predictiveVIA technology, with SieSiemens offering it as an industrialized implementation - which is why the workflow is delivered as a defined cell rather than as a set of analysis tools.

The public follow-on evidence points in the same direction. Siemens' automotive blog describes automated blocked-force extraction applied to an electric power steering component, framing the gain as eliminating manual bottlenecks while moving measurement from days to hours with consistent, repeatable results. Steering systems appear in the master list of supported components, so an EPS-style pilot is a realistic first job: small, high test frequency, and reused across variants. Independent vendor material on component-based transfer path analysis reinforces the business logic - source characterization completed at component level is what allows full-system NVH targets to be set before the first hardware prototype.

What changes in the numbers: manual bench versus automated cell

Conclusion: the certified saving is measurement time; the larger organizational saving is model reuse. Hard figures from the announcement: FRF measurement time 93% lower than conventional methods, and component noise and vibration behavior characterized from days to hours.

DimensionConventional manual extractionAutomated workflow
Characterization cycleDays per componentHours per component
FRF measurement timeBaseline-93%
Operator dependenceHigh; specialist-boundControlled process, no operator-specific step
Repeatability across variants*Re-measurement likelyConsistent results across component variants
Model reuse*Program-specificReusable across multiple system variants
Prototype reliance*Late physical validationEarlier digital twin-based system validation

*Rows marked with an asterisk are WorldIndustrialWeekly interpretation of the stated capabilities, not separately measured figures.

Which mistakes break deployments most often?

  • Confusing blocked forces with contact forces. Contact forces change with the receiving structure; blocked forces are source-intrinsic. Replaying historic contact-force data into a new mounting is the classic prediction failure.
  • Under-engineering the fixture. Compliant adapters or loose shaker mounting corrupt the very FRFs the process is meant to standardize; rigidity is the premise of the method.
  • Automating only the acquisition. If data processing and validation stay manual, the reported time saving is never banked end to end.
  • Treating the model as program property. Without a shared, versioned model library, teams re-measure what a sibling variant already owns.
  • Ignoring the standard's uncertainty guidance. Compliance is about documented uncertainty handling, not about running a script.
  • Skipping bench-side verification. Immediate data checking on the tablet exists to catch setup faults before the component is released; disabling it just relocates the error to simulation.
  • Assuming automation replaces judgement. Test planning, target setting and result acceptance remain engineering decisions.

What should a test owner do in the first 90 days?

Days 1-30: baseline the bottleneck

  • Log bench hours per component per program for the last four quarters, including re-measurements caused by variant changes.
  • Audit sensors, frontends and amplifiers against the Simcenter physical testing portfolio to separate reuse from new spend.
  • Read the ISO 20270 measurement and uncertainty provisions with the CAE lead and agree what a compliant dataset looks like.

Days 31-60: run one instrumented pilot

  • Select a single high-throughput component - a steering actuator or pump is typical - and build the self-measuring fixture with permanently mounted excitation and sensing.
  • Measure before and after with the same acceptance criteria, and record the operator and setup time in both runs.
  • Export results in a neutral format and let the simulation team integrate them into a system model without re-entry.

Days 61-90: industrialize and govern

  • Freeze a standard work instruction covering fixture, plan transfer, extraction, verification and release.
  • Stand up the component model library with naming, revision and variant-eligibility rules.
  • Set two KPIs only: characterization lead time and repeat-run variance; review quarterly against the 93% measurement-time reference point.
  • Extend the cell to a second component family only after the first library entry has been reused at least once.

FAQ

Do existing sensors and frontends have to be replaced?

Not wholesale. The workflow is positioned within the Simcenter physical testing portfolio, combining Simcenter Testlab software, Simcenter SCADAS hardware and Simcenter for Qsources hardware, so the practical first step is a compatibility audit rather than a scrapping exercise.

Is this only useful for automotive NVH?

Automotive is where it was industrialized, with the approach created with Bosch, but the component classes named - electric motors, pumps, compressors, steering systems, actuators - are common to industrial machinery, HVAC, e-bikes and aerospace systems. Any assembly where a source excites a structure through a mounting can use the same logic.

Where does the 93% figure apply?

To FRF measurement time relative to conventional methods. It is a bench-cycle metric, not a whole-program development-time metric; the reuse effect across variants is additional but not quantified in the announcement.

What if our component is not on the supported list?

Validate with a one-off feasibility run before committing to a fixture. Both test-based and CAE-based component representations are supported, so a hybrid entry (measured blocked forces, CAE-derived impedance) is worth pricing as an option.

Does a design change invalidate the stored model?

Mass and stiffness changes at the source usually require re-extraction; changes at the receiver usually do not, because the blocked-force definition is independent of the receiving structure. That asymmetry is what makes model libraries pay back.

Verified sources

  • ISO catalogue entry for ISO 20270 - Acoustics: characterization of sources of structure-borne sound and vibration, indirect measurement of blocked forces: iso.org/standard/90545.html
  • National and regional adoptions: BS ISO 20270:2019 (30 November 2019); EN ISO 20270:2023
  • Siemens newsroom, "Siemens adds AI to Simcenter Testlab", 24 September 2025, Plano, Texas: news.siemens.com/en-us/siemens-simcenter-testlab-2025/
  • Siemens Simcenter blog on blocked forces versus contact forces in transfer path analysis: community.sw.siemens.com
  • Siemens Automotive & Transportation blog on automated component model extraction applied to blocked force testing: blogs.sw.siemens.com/automotive-transportation/
  • Vendor product documentation and further details: siemens.com

Written by Michael Torres for WorldIndustrialWeekly (Industrial Weekly). Story tips and corrections: news@industrialweekly.com.